17. Adjust the Bath Door
All Installations
Check and Adjust the Door Movement
Move the bath door up and down several times with one finger. Check for uneven movement,
rubbing, or shaking.
If the door shimmies or racks, adjust one or both of the mounting brackets inward using the blue
screws and slots, until they are snug against the rollers.
If the door shimmies more when it is fully lowered, adjust the bottom of each mounting bracket
inward using the top screw as a pivot point.
If the door shimmies more when it is fully raised, adjust the top of each mounting bracket inward
using the bottom screw as a pivot point.
NOTE: When properly adjusted the door should move up and down using one finger.
Adjust roller
and mounting
bracket contact.
Lift and lower door several
times with one finger to
establish smooth travel.
Mounting Bracket
Red
Screw
Proper Bumper Adjustment
Bumper
Adjust the limit switches.
Adjust the bumper pads.
Improper Adjustment
(Blue Boot is not Visible)
Limit Switch
Proper Adjustment
(Blue Boot is Visible)
1
2
3
Latch Pin
(Centered)
Blue
Boot
Screw
Strike
Plate
Tighten
nut.
Blue
Screw
Pulley
Assembly
1128532-2-G 30 Kohler Co.