SELF-RIMMING INSTALLATION
Determine the faucet centerline location. Consider the
faucet and handle escutcheon diameters, the length of
the spout, and the clearance between the spout and the
lavatory rim.
Calculate the faucet centerline measurement by first
dividing the escutcheon diameter in half, and then add
1/4” (6mm).
NOTE: Round this calculation up to the nearest 1/16”
(2mm), if necessary.
Fig. #2
Faucet
Centerline
Divide Escutcheon
Diameter in Half, Then
Add 1/4” (6mm)
compliance with all state and local plumbing codes;
a minimum 2” (5cm) distance from the water stream
to the lavatory rim edge. This is important to ensure
adequate clearance for hand washing (refer to
Fig. #3);
a minimum 1/4” (6mm) distance between the faucet
spout and the lavatory rim (refer to Fig. #4).
Redraw the faucet centerline as needed to meet these
criteria. Be sure to use the template line labeled “Rim of
Lavatory”.
Fig. #3
Fig. #4
2” (5cm) Min.
1/4” (6mm) Min.
Air Gap
2” (5cm) Min.
NOTE:
Cut along the backsplash locator line on the template.
Fig. #5
Countertop
Backsplash
Backsplash
Locator Line
Countertop
Faucet Centerline2” (5cm) Min.
Cut-Out Template