Determine the faucet centerline location. Consider the
faucet and handle escutcheon diameters, the length of
the spout, and the clearance between the spout and the
lavatory rim.
Calculate the faucet centerline measurement by first
dividing the escutcheon diameter in half, and then add
1/4” (6mm).
NOTE: Round this calculation up to the nearest 1/16”
(2mm), if necessary.
Fig. #2
Faucet
Centerline
Divide Escutcheon
Diameter in Half,
Then Add 1/4”
(6mm)
compliance with all state and local plumbing codes;
a minimum 2” (5cm) distance from the water
stream to the lavatory rim edge. This is important
to ensure adequate clearance for hand washing
(refer to Fig. #3);
a minimum 1/4” (6mm) distance between the
faucet spout and the lavatory rim (refer to Fig. #4).
Redraw the faucet centerline as needed to meet these
criteria. Be sure to use the line labeled “Rim of Lavatory”.
2” (5cm) Min.
1/4” (6mm) Min.
Fig. #3
Fig. #4
2” (5cm) Min.
Air
Gap
NOTE:
Cut along the backsplash locator line on the template.
Fig. #5
Countertop
Backsplash
Backsplash
Locator Line
Countertop
Faucet Centerline2” Min. (5cm)
Cut-Out Template