Troubleshooting (cont.)
CAUTION: Risk of product damage. This product contains
sensitive electronic components. Use care not to damage pins and
connectors during troubleshooting.
CAUTION: Risk of product damage. Do not insert anything other
than the sensor wire into the sensor wire connector (phone jack) on
the circuit board.
NOTE: For service parts information, visit your product page at
www.kohler.com.
Faucet Troubleshooting Table
Symptoms Probable Causes Recommended Action
1. No water
flow.
A. The supply
stops are
closed.
A. Confirm the supply stops are
open.
B. Handle is in
the closed
position.
B. Rotate the handle to the open
position. Refer to the Faucet
Operation section.
C. The hot
and/or cold
supply hose
is kinked.
C. Confirm the supply hoses are
not kinked. If coiled, maintain
an inside diameter of 3 (76
mm).
D. The outlet
hose is
kinked.
D. Confirm the solenoid valve is
located within 7 (178 mm) to
8 (203 mm) from the faucet
base.
E. Handle LED
is not lit.
E. Refer to the Handle Switch
Troubleshooting Table.
F. Sensor LED
is not lit.
F. Refer to the Sensor
Troubleshooting Table.
G. One or more
screens are
clogged.
G. Refer to the Cleaning the
Screens section.
2. Low water
flow.
A. The supply
stops are
partially
closed.
A. Confirm the supply stops are
fully open.
B. Handle is
partially
closed.
B. Rotate the handle to the full
open position.