Troubleshooting (cont.)
Troubleshooting Table
Symptoms Probable Cause Recommended Action
B. No power to
media module
(media module
status LED is off).
B. Verify media module
is plugged in. Check
power to the outlet.
C. Cable connections
to media module
are loose or
damaged.
C. Check cables and
connections, replace
cables if necessary.
D. PDS fuse is blown. D. Replace the PDS
fuse.
E. Media module is
not assigning an
address to the PDS.
E. Contact a Kohler
Authorized Service
Representative.
F. PDS failure. F. Contact a Kohler
Authorized Service
Representative.
2. Cannot remove
cables from
PDS box.
A. Cables are twisting
when unthreading
strain relief
connections.
A. Unthread strain relief
cap only; then
separate the rubber
stopper from the
strain relief body.
The strain relief body
will be free to
unthread from PDS
box.
3. Water is
leaking from
around the
sprayheads.
A. Nozzle membrane
is not seated
properly.
A. Remove finished
sprayface and verify
the nozzle membrane
is completely seated
in the groove in the
sprayhead. Refer to
the ″Install the
Sprayhead″ section.
Kohler Co. 25 1207716-2-C